设为首页
加入收藏
联系我们
Email-Alert
 

    首页 | 杂志介绍 | 编委成员 | 投稿指南 | 订阅指南 | 过刊浏览 | 临床研究、基础研究模板 | 专家共识、综述模板 | 出版伦理声明 | 帮助

 
王子豪,胡 川,张海泉,王 欣.不同类型的机器人对亚急性期轻度偏瘫的脑卒中患者上肢功能的影响[J].中国康复医学杂志,2025,(3):397~403
不同类型的机器人对亚急性期轻度偏瘫的脑卒中患者上肢功能的影响    点此下载全文
王子豪  胡 川  张海泉  王 欣
山东体育学院,山东省济南市,250102
基金项目:山东省中医药科技项目任务书(2020M047)
DOI:10.3969/j.issn.1001-1242.2025.03.012
摘要点击次数: 751
全文下载次数: 241
摘要:
      摘要 目的:比较外骨骼(exoskeleton,EX)机器人和末端执行器(end-effector,EE)机器人对亚急性期轻度上肢偏瘫脑卒中患者的康复效果。 方法:于2022年2月—2023年2月在山东大学附属省立第三医院康复治疗中心招募30例脑卒中轻度偏瘫患者,采用单盲设计,将30例亚急性脑卒中患者随机分配到EX组或EE组,各15例。两组均在常规康复治疗的基础上分别进行机器人辅助治疗,每次25min,每周5天,共4周。在干预前、2周后和4周后采用上肢Fugl-Meyer评分量表(upper extremity Fugl-Meyer assessment, FMA-UE)、Wolf运动功能测试(Wolf motor function test, WMFT)和改良Barthel指数(modified Barthel index, MBI)对患侧上肢运动功能和日常生活活动能力进行评估。 结果:组内比较结果显示与治疗前相比,两组FMA-UE、WMFT、MBI评分在治疗2周后和4周后均较治疗前有所改善(P<0.05);而只有EX组在治疗4周后与治疗2周后相比仍有改善(P<0.05)。组间比较结果显示治疗4周后,EX组只有FMA-UE评分改善显著优于EE组(P<0.05),WMFT及MBI评分与EE组相比无显著性差异。 结论:EX机器人在改善亚急性期轻度上肢偏瘫的脑卒中患者的上肢运动功能方面优于EE机器人。然而,在改善上肢功能性任务的表现和提高日常生活活动的独立性方面,两者之间没有显著性差异。
关键词:脑卒中  外骨骼机器人  末端执行器机器人  上肢功能
The effect of different types of robotic-assisted therapy on sub-acute stroke patients with mild hemiparesis of the upper extremity    Download Fulltext
Shandong Sport University, Jinan, 250102
Fund Project:
Abstract:
      Abstract Objective: To compare the rehabilitation effects of exoskeleton (EX) robots and end-effector (EE) robots in patients with mild upper limb hemiparesis in the subacute phase of stroke. Method: From February 2022 to February 2023, 30 patients with mild hemiparesis due to stroke were recruited at the Rehabilitation Treatment Center of Shandong University Affiliated Provincial Third Hospital. Using a single-blind design, these patients were randomly assigned to either the EX group or the EE group, with 15 patients in each group. Both groups received robot-assisted therapy in addition to standard rehabilitation treatment. The therapy sessions were conducted five days a week for four weeks, with each session lasting 25 minutes. The affected upper limb was evaluated using the upper extremity Fugl-Meyer assessment (FMA-UE), Wolf motor function test (WMFT), and modified Barthel index (MBI). Assessments were performed at baseline, 2 weeks, and 4 weeks. Result: Within-group comparisons revealed that both groups had significant improvements in FMA-UE, WMFT, and MBI scores at the 2-week and 4-week after treatment compared to baseline (P<0.05). However, only the EX group showed continued improvement between 2 and 4 weeks after treatment (P<0.05). Inter-group comparisons demonstrated that the EX group had significantly greater improvement in FMA-UE scores than the EE group at the 4-week assessment (P<0.05), while no significant differences were observed between the two groups for WMFT and MBI scores. Conclusion: The EX robot demonstrated superior upper limb motor function improvement in patients with mild upper limb hemiparesis in subacute phase of stroke. However, no significant differences were observed between the two robots in improving upper limb functional tasks and enhancing independence in activities of daily living.
Keywords:stroke  exoskeleton robot  end-effector robot  upper extremity function
查看全文  查看/发表评论

您是本站第 50948106 位访问者

版权所有:中国康复医学会
主管单位:中国科学技术协会 主办单位:中国康复医学会
地址:北京市朝阳区樱花园东街,中日友好医院内   邮政编码:100029   电话:010-64218095   

本系统由北京勤云科技发展有限公司设计
京ICP备18060696号-2

京公网安备 11010502038612号